Tuesday, February 17, 2009
What are the guidance documents that govern MDDs?(Microbial Data Deviation Investigations)
•2006 FDA Guidance for Industry - Investigating Out of Specification (OOS) Test Results for Pharmaceutical Production.
•ICH Q6A
•ICH Q7A
•USP 31 <1117> Best Microbiological Practice
•Addressed in PMF Newsletter (Sutton and Settineri)
http://www.microbiologyforum.org/PMFNews/PMFNews.12.11.0611.pdf (Sutton)
http://www.microbiologyforum.org/PMFNews/PMFNews.13.06.0706.pdf (Settineri)
•Addressed in PDA Draft Technical Report
Points to Consider When Investigating Microbiological Data Deviations (MDD) (Formerly known as the Micro OOS Task Force)
•Tangentially addressed in FDA Aseptic Processing Guidance albeit it is focused on sterile products. http://www.fda.gov/cber/gdlns/steraseptic.pdf
Concepts of Design Control
•Design Input & Output
•Design Review
•Design Verification
•Design Validation
•Design Transfer
•Design Changes
•Design History File (DHF
When do we need 510(K)
- Introducing a device into commercial distribution for the first time
- Different intended use for a device already in commercial distribution
- Indicated by claims made for a device in labeling/advertising
- Note: Prescription use to over-the-counter use is a major change in intended use
3. Change to a device that could significantly affect its safety or effectiveness
- Burden is on you to decide whether a modification “could significantly affect safety or effectiveness.”
- If no submission, justification should be recorded in your change control records
510(K) is not required under following conditions.
•Device is not marketed or commercially distributed
–Example: clinical trials (regulated by 21 CFR 812)
•Distributor of another firm's U.S.-manufactured device
•Device is not manufactured by your company, but is marketed or commercially distributed by your company
–Labeling shall reveal connection with manufacturer: "Manufactured for Life-Tech" or "Distributed by Life-Tech"
•For repackager or relabeler, if labeling or condition of the device is not significantly changed
–Labeling must be same as 510(k): indications for use, warnings, contraindications
•Device in commercial distribution before 5/28/76
–Must be documented
Related Training - http://www.complianceonline.com/ecommerce/control/trainingFocus?product_id=701016&channel=priya
ASTM E 2500 – 07, What is it? - salient features
•“The overall objective is to provide manufacturing capability to support defined and controlled processes that can consistently produce product meeting defined quality requirements.”
this is Approved June 1, 2007
–An ASTM Standard
–A voluntary consensus standard
–It has legal relevance
•The term “Validation” appears only 1 time
–“quality”, (not Quality Assurance or Quality Unit) appears 44 times
–“expert” appears 21 times
–“critical” appears 20 times
•The terminology implies knowledge of what’s important to your system
What ASTM E 2500 Applies To
Pharmaceutical and biopharmaceutical manufacturing systems:
- Facility equipment
- Process equipment
- Supporting utilities
- Process monitoring and control systems
- Automation Systems that have the potential to affect product quality and patient safety
Attend the detailed training to know following areas. Click here http://www.complianceonline.com/ecommerce/control/trainingFocus?product_id=701165&channel=priya - Review of how these ASTM and ICH approaches can simplify the qualification process.
- Documentation of design.
- Risk mitigation by design review and operational practices.
- The role of subject matter experts.
- Use of risk management techniques to drive the extent of systems verification and level of documentation detail.
- Acceptability of well-managed changes to systems.